DATACENTERS

GENESISMINING DATACENTER

GENERAL

Buying hashrate of equipment hosted in the GenesisMining datacenter you rest assured that the mining equipment is placed, set up and maintained by a team of qualified personnel.

FACILITY

The datacenter is built by a first-class industrial construction company with dozens of years of experience in such projects.

SECURITY AND COMPLIANCE

Security is a critical factor of a datacenter. We have ensured compliance with the highest international standards with sophisticated manned, hardware and software security systems.

ELECTRICITY

Power is provided by independent power grids with a separate generator and a backup batteries.

CONNECTION

Internet connection is provided by redundant fiber connections to different Iceland internet exchanges.

TECHNICAL SUPPORT

24/7 maintenance provided by professional on-site support to effectively resolve any technical issues.

ADVANTAGES

Scalability and a choice of mining plans

Carrier neutral, redundant connections

Secure facility and flexibility

Designed for cryptocurrency mining equipment

ISKE standard compliance

TECHNICAL SPECIFICATIONS

DATACENTER FEATURES

Mining Equipment Hosting

Racks up to 8kW

Internet Connectivity

Remote Administration Racks

APC / Rittal

GENERAL FEATURES

Structure: Reinforced concrete

Floors: Ground and raised

Area: Low flood area. DC rooms 20m above sealevel

On-site personnel: Electrical engineers,
Network engineers
, Security personnel,
Monitoring staff

STANDARDS COMPLIANCE

Data Centre: ISKE standard compliant rooms, TIER level 2

Certifications: EVS-EN ISO 9001:2008 Certificate for Quality Management System

Qualifications: ITIL qualified personnel

CONNECTIVITY

Features: 2 independent optic fiber routes

Operators: TeliaSonera Elion

Technologies: SDH, MPLS

POWER

External feed: 4 independent connections to the national power grid

Power: 2MW

Voltage: 4x 10kV

Sub-station: Automatic Transfer Switch (ATS)

UPS systems: N+1 redundancy configuration

Generators: Diesel, 850kVA in N+1 configuration. Separately housed

Fuel supply: Fuel for 48 hours of continual service at site

Cabling: Waterproof and fire resistant cabling on 3 level trays

COOLING

Layout: Hot and cold aisle layout

Features: Traditional and free air cooling with heat exchangers and air conditioners

Redundancy: Air conditioners in N+1 redundancy

Temperature: 20-24°C – According to industry standards

Humidity: According to industry standards

SAFETY & PROTECTION

Fire: Gas extinguishing fire suppression system

Water: Drainage systems with pumps in N+1 redundancy

Intrusion: Detection with sensors, video and on-site personnel

Surveillance: 24h on-site manned surveillance,
Video surveillance